Spacer Graft Study

Brief Summary
To determine which of three types of spacer grafts (hard palate vs autologous ear cartilage vs Enduragen) are the most effective in lower eyelid retraction repair outcomes as measured by MRD2 (margin to reflex distance 2)
Brief Title
Spacer Graft Study
Detailed Description
Lower eyelid retraction is a common eyelid malposition, typically caused by thyroid eye disease, excessive resection of skin in a cosmetic lower eyelid blepharoplasty, vertical rectus muscle recession, facial nerve paralysis, or a normal anatomical variant. When the lower eyelid is displaced inferiorly, exposing sclera between the limbus and the eyelid margin, symptoms can vary from ocular irritation and discomfort to vision threatening corneal decompensation. If medical management does not suffice, surgery is indicated.

Although lower eyelid retractor lysis alone has been described, supporting material (spacer graft) placed to augment the posterior lamella is generally required for more effective elevation of the eyelid. Various materials have been utilized, including autologous auricular cartilage, bovine acellular dermal matrix, porcine acellular dermal matrix, hard palate mucosa, dermis and dermis fat grafts. Previous studies on acellular dermal matrix use in lower eyelid retraction repair consist of retrospective efficacy studies with only 2 comparative studies. However, conflicting results raised doubt as to which material was superior. In addition, a prospective, randomized comparative study of spacer grafts used for lower eyelid retraction repair was done comparing autologous auricular cartilage, porcine acellular dermal matrix, and bovine acellular dermal matrix. The results yielded no statistically significant difference in surgical outcomes and complications. As of now, surgery with any of the spacer grafts, including autologous hard palate, is accepted as standard of care.

This study is designed to determine whether using hard palate as a spacer graft will have statistically significant different surgical outcomes and complications as compared to autologous ear cartilage and porcine acellular dermal matrix spacer grafts. Although studied separately, this has not been studied before in a prospective randomized manner and may prove to demonstrate improved surgical results and decreased complications. This can guide future choice of spacer graft used in lower eyelid retraction repair surgery.
Categories
Central Contacts
Central Contact Role
Contact
Central Contact Phone
(978) 886-7122
Central Contact Email
abarmett@montefiore.org
Completion Date
Completion Date Type
Estimated
Conditions
Eyelid Diseases
Eyelid Droop
Eligibility Criteria
Inclusion Criteria:

* Underwent lower eyelid retraction repair requiring a spacer graft between July 1, 2019 and July 1, 2022

Exclusion Criteria:

* Younger than 18 years old
* Required concurrent surgeries (e.g., midface lift or full thickness skin graft) or required further surgeries on the operated eyelid within the 6 months postoperatively
* Patients with less than 1-month follow up will be excluded from all outcome analysis and those without postoperative 6-month data will be excluded from the postoperative month 6 MRD2 calculation
Inclusion Criteria
Inclusion Criteria:

* Underwent lower eyelid retraction repair requiring a spacer graft between July 1, 2019 and July 1, 2022

Gender
All
Gender Based
false
Keywords
Retraction Repair
Hard Palate
Autologous Ear Cartilage
porcine acellular dermal matrix
spacer graft
Healthy Volunteers
No
Last Update Submit Date
Minimum Age
18 Years
NCT Id
NCT04140734
Org Class
Other
Org Full Name
Montefiore Medical Center
Org Study Id
2019-10410
Overall Status
Recruiting
Phases
Not Applicable
Primary Completion Date
Primary Completion Date Type
Estimated
Official Title
Study Protocol for Comparison of Lower Eyelid Retraction Repair With Hard Palate, Autologous Ear Cartilage, and Porcine Acellular Dermal Matrix Spacer Grafts
Primary Outcomes
Outcome Description
Lower Eyelid Height will be measured via Margin Reflect Distance 2 (MRD2). Photographs taken during study visits will analyze the effectiveness of the spacer grafts with respect to lower eyelid retraction repair. MRD2 is the distance in millimeters between the pupillary light reflex and the lower eyelid margin with the patient looking at a light reflex in primary gaze. Results will be summarized and reported by study arm using basic descriptive statistics. A normal MRD2 is about 4. The higher the number for MRD2, the more severe the retraction. Postoperatively, a lower MRD2 indicates a better surgical outcome.
Outcome Measure
Lower Eyelid Height
Outcome Time Frame
Preoperatively, and at 1 week, 1 month, 3 months and 6 months post-operatively
Secondary Outcomes
Outcome Description
Post-Surgical Complications will be summarized using specific complications as graded by either the examiner or the patient. Specifically, conjunctival injection and eyelid swelling will be graded by the examiner on a scale of 0 to 10 where "0" indicates no visible injection or swelling (normal), respectively and "10" is indicative of the most severe level of conjuctival redness or swelling, respectively. Similarly, tearing, itching, and discomfort will be individually graded by the patient on a scale of 0-10 wherein "0" is indicative of no tearing, itching, or discomfort, respectively and "10" is indicative of maximal tearing, itching, and discomfort, respectively. Results will be summarized and reported by study arm using basic descriptive statistics.
Outcome Time Frame
Preoperatively, and at 1 week, 1 month, 3 months and 6 months post-operatively
Outcome Measure
Post-Surgical Complications
Start Date
Start Date Type
Actual
Status Verified Date
First Submit Date
First Submit QC Date
Std Ages
Adult
Older Adult
Maximum Age Number (converted to Years and rounded down)
999
Minimum Age Number (converted to Years and rounded down)
18
Investigators
Investigator Type
Principal Investigator
Investigator Name
Anne Barmettler
Investigator Email
abarmett@montefiore.org